![]() a Thermo Aquatuner cooling Water will move ten times as much heat per second as a Thermo Regulator cooling Steam. Common liquid coolants tend to have higher specific heat capacity than gas coolants when their temperature ranges overlap, and even with the same SHC the different throughput of liquid versus gas pipes means that e.g. While both machines reduce temperature of their working fluid by the same amount, the Aquatuner moves considerably more heat. The Thermo Aquatuner is similar to the Thermo Regulator, but processes liquids instead of gases. Steam and Gas Super Coolant are higher, but are also high temperature. Though as of Meep's Mandatory Recreation Pack Update Hydrogen liquifying can be achieved using the fact that cooling 1/10 of maximum packet size of gas below its condensation point will not break the pipe.Īny gas can be used, but Hydrogen is the best option as it has the lowest condensation temperature and a high heat capacity. It can produce liquid oxygen, but a Thermo Aquatuner is more efficient if you have access to Super Coolant. Whilst the Regulator has no minimum output temperature, it is hardly capable of producing liquid hydrogen, as hydrogen has the lowest condensation temperature and therefore cannot be produced without damaging pipes. The Regulator does not respect condensation temperatures of gases, and will damage the output pipe if gases are cooled below their condensation temperature. It is therefore best to use gases with a high SHC ( Hydrogen) and to ensure all packets sent in are 1 kg (it consumes 240 J per packet, not per 1 kg), in order to make the most of the 240 W power requirement. Each packet of gas has 14 ☌ removed from it, regardless of the specific heat capacity of the gas or the amount. The amount of heat moved depends on the type and amount of gas piped in. As this is heat-neutral, cooling it with its own output will cause it to maintain its temperature, assuming no other heat sources or sinks are present. Thermo Regulator (as well as the Thermo Aquatuner) works by taking heat from anything piped into it and applying that heat to itself, and does not produce its own heat. The Thermo Regulator cannot be immersed in liquid, but it can still be immersed in gases, including Steam.The tiles that the Thermo Regulator is sitting on can be Mesh Tiles, however, so there can be liquid (and gases) underneath the Thermo Regulator.Unlike a Thermo Aquatuner, it cannot be submerged in liquid, though liquid under 50kg/tile (Flooding status) can be used to facilitate faster cooling. If the environment around the Thermo Regulator can not absorb its heat, it will quickly overheat. Thermo Regulator cools the Gas piped through it and absorbs the Heat.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |